ORDERS OVER $99 UNLOCK FREE* SHIPPING

0

Your Cart is Empty

Victron Phoenix Inverter 24VDC - 250VA - 120VAC - VE.Direct - NEMA 5-15R

Stock: 5 units left

Inverter 24VDC - 250VA - 120VAC - VE.Direct - NEMA 5-15R

Inverters allow you to power domestic equipment - requiring 230V/120V AC - using 'leisure' or 'automotive' batteries rated at 12V, 24V, or 48VDC. 

The VE.Direct port can be connected to:

  • A computer (VE.Direct to USB interface cable needed)
  • Apple and Android smartphones, tablets, MacBook, and other devices (VE.Direct Bluetooth Smart dongle needed)

Fully configurable:

  • Low battery voltage alarm trip and reset levels
  • Low battery voltage cut-off and restart levels
  • Dynamic cut-off: load-dependent cut-off level
  • Output voltage 210 - 245V
  • Frequency 50 Hz or 60 Hz
  • ECO mode on/off and ECO mode sense level

Monitoring:

  • In- and output voltage, % load, and alarms
  • Please get in touch with your dealer for any returns, repairs, or support issues related to this product.

Phoenix Inverter 24/250 Specifications:

  • Continuous Power at 25°C: 250VA
  • Continuous Power at 25°C / 40°C: 200 / 175W 
  • Peak Power: 400W 
  • Output AC Voltage / Frequency (adjustable): 120VAC +/- 3%
  • Input Voltage Range: 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V
  • DC Low Shut Down (adjustable): 9,3 / 18,6 / 37,2V
  • Dynamic (Load Dependent) DC low shut down (fully configurable): Dynamic cut-off
  • DC Low Restart and Alarm (adjustable): 10,9 / 21,8 / 43,6V
  • Battery Charged Detect (adjustable): 14,0 / 28,0 / 56,0V
  • Maximum Efficiency: 87 / 88 / 88% 
  • Zero-Load Power: 4,2 / 5,2 / 7,9W 
  • Default Zero-Load Power in ECO Mode (default retry interval: 2,5 s, adjustable): 0,8 / 1,3 / 2,5W
  • ECO Mode Stop and Start Power Setting: Adjustable
  • Protection: a - f
  • Operating temperature Range: -40 to +65°C (fan-assisted cooling) / Derate 1,25% per °C above 40°C
  • Humidity (non-condensing): Max 95%

Enclosure:

  • Material & Color: Steel chassis and plastic cover (blue Ral 5012)
  • Battery-Connection: Screw terminals
  • Maximum Cable cross-Section 10mm^2 / AWG8 
  • Standard AC outlets 230V: Schuko (CEE 7/4), IEC-320 (male plug included), UK (BS 1363), AU/NZ (AS/NZS 3112), 120V: Nema 5-15R, GFCI
  • Protection Category: IP 21
  • Weight: 2,4kg / 5,3lbs
  • Dimensions (h x w x d, mm) / (h x w x d, inch): 86 x 165 x 260 mm / 3.4 x 6.5 x 10.2 in.

Accessories:

  • Remote On-Off: Yes
  • Automatic Transfer Switch: Filax

Quick Guide (pdf)